SC-600-0R7S2 model specifications:
Type
Power Supply Capacity (kVA)
Input Current (A)
Output Current (A)
Adapter motor
(kW) (HP)
Single-phase power supply: 220V 50/60Hz
SC-600-0R7S2
One point five
Eight point two
Three point eight
Zero point seven five
One
SC-600-0R7S2 product features:
1. Complete voltage level, covering: 220V, 380V, 660V.
2. Support a variety of communications: Modbus (profibus-dp, can-open and other optional cards).
3. Support a variety of speed feedback cards: various types of rotary encoders and transformers.
4. Quick successive current limiting function to ensure that the load does not trip and output large moments.
5, 3 A/D sampling, suitable for most industrial control occasions, flexible settings, improve field applications.
6. High-quality algorithms, whether open-loop vector, closed-loop vector or V/F control, can meet the speed control requirements, and the low-frequency torque is large and stable.
7. Support closed-loop vector operation of synchronous motor.
8. Supporting torque control. In V/F control, current and speed tracking, V/F separation, and effective elimination of light load oscillation, etc., the *** output frequency can reach 3200Hz.
9. The special function of instantaneous stop and stop can speed up and stop when power failure, prevent long-time inertial rotation of machinery, make it safer and complete debugging quickly.
10. It has two sets of motor parameter setting, *** switching, timing PLC operation, PID operation and user-customized parameter set.
11. The "one-key shuttle" keyboard supports hot-swapping and can store/copy functional parameters.
12. It can be used in winding control, multi-motor driving load distribution under the same load, etc.
13. Inverter spare parts selection includes: energy *** unit, DC brake unit, energy-saving control cabinet and so on.
SC-600-0R7S2 has excellent performance:
- Excellent Torque and Speed Control Performance
_Speed control accuracy can reach positive or negative 1 rpm at 100% torque. Under sensorless vector control, the torque response is less than 20 ms. With sensor vector control, the torque response is less than 5 ms.
_Suitable for high-speed CNC spindles above 10000 revolutions;
_deceleration stop, superior performance, 0.1 seconds fast and accurate parking;
_Suitable for precision machine tools, synchronous operation, oil pump and other load calibration.
--The world's leading speed sensorless vector control algorithm
_Sensorless vector control can block the movement and output 150% rated torque at 0Hz.
_The parameter identification method of independent patent technology can accurately learn the parameters of rotating or stationary motors.
Convenient debugging, simple operation, *** higher control accuracy and response speed;
It can be used in winding control, multi-motor driving load distribution under the same load and other occasions.
High starting torque characteristics
_SC600 converter can *** 150% start-up torque (sensorless vector control) at 0.5Hz and *** 180% zero-speed torque (sensorless vector control) at 0Hz.
_Suitable for cranes, mud machines, mixers, gantry planers, injection moulding machines, extruders and other loads when starting resistance is high and acceleration and deceleration is fast.
SC-600-0R7S2 has powerful functions:
Torque of protective machinery***
_SC600 converter can *** torque ***. When the torque exceeds the *** torque that the machine can bear, the converter can better protect the safety of the equipment under the premise that the set *** torque can give full play to the inherent efficiency of the machine.
Reliable Torque *** (Torque *** Value 150%) is suitable for cranes, extruders and other loads.
- Instantaneous
_This function only in the instantaneous power outage when the frequency converter will not stop, in the instantaneous power outage or sudden voltage reduction, the frequency converter reduces the output speed, through the load *** energy, supplement the voltage reduction, in order to maintain the frequency converter to continue working in a short time;
_Suitable for chemical fibers, textile production and other loads.
Fast Current Limiting Function
Fast current limiting function can avoid frequent over-current ***. When the current exceeds the current protection point, the fast current limiting function can quickly *** in the current protection point, thus protecting the safety of equipment and avoiding over-current *** caused by sudden load or interference.
- Speed tracking function
Patented speed tracking algorithm; Fast and smooth, zero impact *** motor *** speed, only for high inertia centrifuges, induced draft fans, electric vehicles and other occasions.
SC-600-0R7S2 Technical Specification:
project
Specifications
Basic functions
*** Frequency
Vector control: 0-300Hz
V/F control: 0-3200Hz
carrier frequency
0.5kHz~16kHz
Carrier frequency can be adjusted automatically according to load characteristics.
Input Frequency Resolution
Digital Settings: 0.01Hz
Simulated Settings: *** Frequency * 0.025%
control mode
Open-loop vector control (SVC)
Closed-loop vector control (FVC)
V/F Control
Start-up Torque
Model G: 0.5Hz/150% (SVC); 0Hz/180% (FVC)
Model P: 0.5Hz/100%
Speed range
1:100 (SVC)
1:1000 (FVC)
Steady Speed Accuracy
+0.5% (SVC)
+0.02% (FVC)
Torque Control Accuracy
+5% (FVC)
Overload capacity
Model G: 150% rated current 60s; 180% rated current 3s.
Model P: 120% rated current 60s; 150% rated current 3s.
Torque Lifting
Automatic Torque Lifting; Manual Torque Lifting 0.1%~30.0%
V/F curve
Three ways: straight line type; multi-point type; N-power V/F curve
(1.2, 1.4, 1.6, 1.8, 2)
V/F Separation
Two ways: total separation and semi-separation
Acceleration and deceleration curve
Acceleration and deceleration of straight line or S curve.
Four acceleration and deceleration times,
Acceleration and deceleration time range 0.0-6500.0s
DC brake
DC braking frequency: 0.00Hz ~***
Braking time: 0.0s~36.0s
Braking action current value: 0.0%~100.0%
Point control
Point frequency range: 0.00Hz ~ 50.00Hz.